| MOISTURE ANALYZERS |
 | MOD 1 MOISTURE ANALYZER Housed in a rugged ABS plastic 1/4 DIN enclosure suitable for bench or panel mounting. |
 | MOD 2 MOISTURE ANALYZER Similar to the MOD 1, except that it is housed in a NEMA 4 enclosure for those applications where dirt, water, or corrosive atmospherers cause a problem |
 | MOD 3 PORTABLE MOISTURE ANALYZER Designed for specific process applications where sampling of high pressure gass and portability are required. It consists of a built-in sampling system, sensor, and the MOD 1 electronics, all housed in a compact, rugged, ABS plastic case designed to withstand field abuse. The MOD 3 was designed for use in crtical applications such as monitoring SF6 gases in circuit breakers and moisture in natural gas transmission systems. |
MOISTURE ANALYZER AVAILABLE OPTIONS AND SPECIAL CONFIGURATIONS
ADVANCED ALUMINUM OXIDE SENSOR
|
| FROSTPOINT / DEWPOINT INDICATORS |
 | LOW PRESSURE Model 10310-9 Frostpoint/Dewpoint Indicator detects and indicates the frostpoint or dewpoint of gas sampled from a low pressure air system, from 80 to 150 psig. |
 | HIGH PRESSURE Model 10310-24 Frostpoint/Dewpoint Indicator detects and indicates the frostpoint or dewpoint of gas sampled from a high pressure air system, from 3000 to 5000 psig. |
|   |
| INSTRUMENT TEST GAGE VALVE |
 | REMOVABLE STEM The ADC Gage Valve is designed for use in 0 to 6000 psi fluid systems. Removal of the soft seat cap allows periodic calibration of the line gage and sampling of the fluid media without shutting down the pressurized system. With the elimination of swaging on the bonnet it provides an absolute, foolproof arrangement where it is impossible to undo the bonnet or the stem during operation. |
 | REMOVABLE STEM AND UNION BONNET The ADC Gage Valve is designed for use in 0 to 6000 psi fluid systems. Removal of the soft seat cap allows periodic calibration of the line gage and sampling of the fluid media without shutting down the pressurized system. With the elimination of swaging on the bonnet it provides an absolute, foolproof arrangement where it is impossible to undo the stem during operation. |
 | REMOVABLE STEM AND UNION BONNET-ANGLE TYPE The ADC Gage Valve is designed for use in 0 to 6000 psi fluid systems. Removal of the soft seat cap allows periodic calibration of the line gage and sampling of the fluid media without shutting down the pressurized system. With the elimination of swaging on the bonnet it provides an absolute, foolproof arrangement where it is impossible to undo the stem during operation. |