| SERIES CODE | C MAX DIM |
| A | 1.156 |
| B | 1.156 |
| C | 1.000 |
| D | 1.214 |
| E | 1.214 |
| F | 1.156 |
| FM | 1.156 |
| G | 1.237 |
| H | 1.654 |
| J | .809 |
| K | .904 |
| KA | .759 |
| KB | .799 |
| KC | .745 |
| KD | .904 |
| L | .873 |
| M | .966 |
| N | 1.000 |
| P | 1.154 |
| R | 1.123 |
| T | 1.154 |
| U | 1.232 |
| W | 1.039 |
| X | .994 |
|     |
ENTRY SIZE | D MAX DIA | E MAX DIA | F MAX DIA | G MAX DIM | H MAX DIM | CABLE ENTRY |
| MAX | MIN |
| 02 | N / A | .840 | .781 | N / A | N / A | .250 | .125 |
| 03 | .858 | .965 | .906 | 1.36 | 1.86 | .375 | .156 |
| 04 | .858 | 1.090 | 1.031 | 1.49 | 1.98 | .500 | .281 |
| 05 | 1.112 | 1.215 | 1.156 | 1.61 | 2.11 | .625 | .406 |
| 06 | 1.218 | 1.340 | 1.281 | 1.74 | 2.23 | .750 | .531 |
| 07 | 1.345 | 1.465 | 1.406 | 1.86 | 2.36 | .875 | .656 |
| 08 | 1.468 | 1.590 | 1.531 | 2.11 | 2.61 | 1.000 | .781 |
| 09 | 1.593 | 1.715 | 1.656 | 2.11 | 2.61 | 1.125 | .906 |
| 10 | 1.969 | 1.840 | 1.781 | 2.34 | 2.73 | 1.250 | 1.031 |
| 11 | 1.969 | 1.965 | 1.906 | 2.36 | 2.86 | 1.375 | 1.156 |
| 12 | 2.219 | 2.090 | 2.031 | 2.61 | 3.11 | 1.500 | 1.281 |
| ORDER NUMBER | J MAX DIM | K MAX DIM |
| 01 - 06, 08, 52, 54, 64, 65 | 1.82 | 1.98 |
| 07, 09 - 12, 14, 53, 55 - 58, 67, 69, 70 | 2.08 | 2.23 |
| 13, 15, 16, 18 - 24, 59 - 61, 71, 72, 74 | 2.45 | 2.61 |
| 25 - 29, 49, 50, 62, 77 | 2.70 | 2.86 |
| 30 - 40, 63 | 3.45 | 3.61 |
| 41 - 48 | 3.82 | 3.98 |
|
NOTES:
- Identified Per MIL-STD-130
- Plating Index for Finishes Available
- Material; Adapter Components; Aluminum Alloy Per QQ-A-225 or QQ-A-591. Spring Screws and washers, stainless steel. Elastomers, Standard Neoprene Per MIL-R-3065 or Silicone (See Note 4) Per ZZ-R-765.
- Insert the following letter(s) for the function required:
'R' - Elbow with RFI Rings. 'E' - Environmental (Neoprene Elastomers, Non-RFI). 'S' - Environmental (Silicone Elastomers, Non-RFI). 'RE' - RFI & Environmental (Neoprene Elastomers) 'RS' - RFI & Environmental (Silicone Elastomers)
- Insert letter 'C' for 'C' nut (no strian relief) (omit letter for strain relief clamp)
- Two-Piece assembly supplied when cable entry exceeds connector insert Dia. D, G, and H dimensions apply to two- piece assemblies only
- SE97-***-* ground support ring (ordered sperately is recommended for all rfi assemblies and when shield support ring must be used for sufficient grounding. (see SE97)
DIMENSIONS ARE IN INCHES Tolerance, unless otherwise specified: .X ± .03 (1.5) .XX ± .010 (0.8) .XXX ± .005 (0.4) Angles: ± 5 degrees Fractions ± 1/32
Click here for this part's assembly procedure (AP27)

|