Overall Shield Termination click here for Individual and Overall Shield Termination CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 1: TEMPORARILY ASSEMBLY SLEEVE TO CONNECTOR CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 2: SLIDE NUT UP CABLE AWAY FROM TERMINATION AREA SO AS NOT TO INTERFERE WITH SUBSEQUENT ASSEMBLY STEPS CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 3: INSERT CABLE INTO SLEEVE AND BOTTOM AGAINST CONNECTOR HOLD CABLE IN POSITION AND MARK JACKET AT END OF SLEEVE CLICK HERE TO VIEW A LARGER IMAGE ![]() SETP 4: DISASSEMBLE SLEEVE FROM CONNECTOR AND SLIDE SLEEVE UP THE CABLE WITH NUT. (SLIDE WIRE RING UP CABLE AFTER SLEEVE IF APPLICABLE) CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 5: TRIM CABLE JACKET 1/2 INCH PLUS LENGTH OF WIRE THAT WILL PROTRUDE INSIDE OF CONNECTOR, BEHIND MARK (REF STEP 3) BEING CAREFUL NOT TO CUT OVERALL SHIELD CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 6: PREPARE OVERALL SHIELD BY FLARING OUT AND SECURING AGAINST OUTER PERIPHERY OF CABLE AND SPOT TIE (TERMPORARILY). STEP 7: TERMINATE CONDUCTORS IN ACCORDANCE WITH NORMAL PRACTICES STEP 8: ASSEMBLE SLEEVE TO CONNECTOR AND TIGHTEN CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 9: FLARE SHIELD OVER REAR OF SLEEVE SLIDE DOWN NUT AND THREAD ONTO SLEEVE SECURLY AND TORQUE TO 75 INCH POUNDS AND TRIM ANY EXPOSED SHIELD STRANDS AT FOWARD END OF NUT STEP 10: SHRINK BOOT MAY BE INSTALLED AT THIS TIME Individual and Overall Shield Termination click here for Overall Shield Termination CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 1: TEMPORARILY ASSEMBLE SLEEVES (1) AND (2) TOGETHER AND ASSEMBLE SLEEVES TO CONNECTOR CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 2: SLIDE NUT UP CABLE AWAY FROM TERMINATION AREA SO AS NOT TO INTERFERE WITH SUBSEQUENT ASSEMBLE STEPS. CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 3: INSERT CABLE INTO SLEEVES AND BOTTOM AGAINST CONNECTOR. HOLD CABLE IN POSITION AND MARK JACKET AT END OF SLEEVE (2) CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 4: REMOVE CABLE FROM SLEEVES REMOVE SLEEVE(2) FROM SLEEVE(1) AND SLIDE SLEEVE (2) AND GROUND RING UP CABLE WITH NUT CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 5: TRIM CABLE JACKET 1/2 INCH PLUS LENGHT OF WIRE THAT WILL PROTRUDE INSIDE OF CONNECTOR BEHIND MARK BEING CAREFUL NOT TO CUT OVERALL SHIELD STEP 6: INSERT CABLE IN TO SLEEVE(1) AND BOTTOM AGAINST CONNECTOR, HOLDING CALBE IN PLACE MARK OVERALL SHIELD AT END OF SLEEVE. CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 7: DISCONNECT SLEEVE(1) FROM CONNECTOR AND SLIDE SLEEVE UP CABLE WITH OTHER COMPONENTS (SLIDE WIRE SEAL RING UP CABLE AFTER SLEEVE IS APPLICABLE) CLICK HERE TO VIEW A LARGER IMAGE ![]() SETP 8: TRIM OVERALL SHIELD 1/2 INCH FROM MARK TOWARDS END OF CABLE BEING CAREFUL NOT TO CUT INDIVIDUAL SHIELS, FOLD BACK AND SPOT TIE. CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 9: EXTRACT WIRES FROM INDIVIDUAL SHIELDS 1 INCH BACK FROM CABLE JACKET (REF AP95) FOLD BACK INDIVIDUAL SHIELDS AND SPOT TIE STEP 10: TERMINATE CONDUCTORS IN ACCORDANCE WITH NORMAL PRACTICES STEP 11: SLIDE DOWN SLEEVE(1) AND ASSEMBLY TO CONNECTOR AND TIGHTEN CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 12: UNTIE INDIVIDUAL SHIELDS SLIDE GROUND RING DOWN FLARE SHIELDING OUT, OVERA ND AROUND GROUND RING STEP 13. SLIDE GROUND RING TINO PLACE IN TAPERED BORE AT REAR OF SLEEVE(1) TRIM EXCESS SHIELD AND SPOT TIE IF NECESSARY CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 14: SLID SLEEVE(2) AND THREAD ONTO SLEEVE 1 AND TIGHTEN CLICK HERE TO VIEW A LARGER IMAGE ![]() STEP 15: FLARE OVERALL SHIELD OVER REAR OF SLEEVE(2) SLIDE DOWN NUT AND THREAD ONTO SLEEVE SECURELY AND TORQUE TO 75 INCH POUNDS TRIM ANY EXPOSED SHIELD STRANDS AT FORWARD END OF NUT STEP 16: SHRINK BOOT MAY BE INSTALLED AT THIS TIME |
![]()
|
|