    SUGGESTED ASSEMBLY PROCEDURE
  1. Temporarily assemble sleeve to connector.
  2. Place crimp ring on cable or harness, and keep it at a convenient distance from end of cable so it will not interfere with subsequent assembly steps.
  3. Insert cable into sleeve and bottom against connector. Hold cable in position and mark outer shield. (or jacket) at rear end of sleeve.
  4. Remove sleeve from connector and place on cable with crimp ring.
  5. Trim outer shield (and jacket if necessary) at mark made in step (c) above.
  6. Prepare and terminate individual conductors in accordance with established practices.
  7. Assemble sleeve to connector and tighten securely.
  8. Flare shield over rear crimping area of sleeve and slide crimp ring into place over shield.
  9. Hold crimp ring and shiled in position as in step (h) and crimp with proper tool, making sure accepted crimping pracrtices are observed. Trim any exposed shield strands at forward end of crimp ring.
  10. Depending on the particular application, subsequent molding, potting or shrink boot installation may be accomplished at this point, using the knurled surface or molding grooves provided on the adapter body.